October 23, 2009
Symptoms
Messages are not transferred. Following warning is reported into Event Log:
Report for message xxx of xxx from xxxx.
Delivery report:
Status: Not completed
xxx@xxx:
Not delivered. No such host is known.
Cause
Narawen Inox POP3 Connector used reverse DNS lookup to retrieve mail host name. In some network configurations this query fails with error message ‘No such host is known’.
Solution
Upgrade to the latest release of Narawen Inox POP3 Connector.
Applies to
Narawen Inox POP3 Connector 5.2 SR1 (2008-02-05)
Narawen Inox POP3 Connector 5.2 (2007-11-14)
Narawen Inox POP3 Connector 5.1 SR1 (2006-09-25)
Narawen Inox POP3 Connector 5.1 (2006-06-14)
Narawen Inox POP3 Connector 5.0 (2005-11-10)
Leave a Comment » |
Narawen Inox POP3 Connector | Tagged: 5.0, 5.1, 5.1 SR1, 5.2, 5.2 SR1, dhcp, dns, host name, inox, network, warning |
Permalink
Posted by Narawen Software
October 23, 2009
Symptoms
SMTP server reports authentication error despite correct credentials configured. It happens when dynamic addressing is in use.
Cause
There was a problem with Narawen Inox POP3 Connector. It was not sending authentication details to SMTP server when dynamic addressing was in use.
Solution
Upgrade to latest release of Narawen Inox POP3 Connector.
Applies to
Narawen Inox POP3 Connector 5.2 SR1 (2008-02-05)
Narawen Inox POP3 Connector 5.2 (2007-11-14)
Narawen Inox POP3 Connector 5.1 SR1 (2006-09-25)
Narawen Inox POP3 Connector 5.1 (2006-06-14)
Narawen Inox POP3 Connector 5.0 (2005-11-10)
Leave a Comment » |
Narawen Inox POP3 Connector | Tagged: 5.0, 5.1, 5.1 SR1, 5.2, 5.2 SR1, authentication, error, inox, smtp |
Permalink
Posted by Narawen Software
October 23, 2009
Symptoms
Messages are not delivered by Narawen Inox POP3 Connector when dynamic addressing is in use.
Cause
Narawen Inox POP3 Connector was case-sensitive while recognizing message headers which could cause them to be ignored.
Solution
Upgrade to latest release of Narawen Inox POP3 Connector.
Applies to
Narawen Inox POP3 Connector 5.2 SR1 (2008-02-05)
Narawen Inox POP3 Connector 5.2 (2007-11-14)
Narawen Inox POP3 Connector 5.1 SR1 (2006-09-25)
Narawen Inox POP3 Connector 5.1 (2006-06-14)
Narawen Inox POP3 Connector 5.0 (2005-11-10)
Leave a Comment » |
Narawen Inox POP3 Connector | Tagged: 5.0, 5.1, 5.1 SR1, 5.2, 5.2 SR1, dynamic addressing, inox |
Permalink
Posted by Narawen Software
October 23, 2009
What is BCC address
When the sender of the e-mail message decides to hide recipients from being aware of each other he can use BCC (Blind Carbon Copy) address field while editing the message.
The e-mail addresses put in BCC field are not stored inside message header set like regular “To:” or “CC:” fields.
This can cause the situation that POP3 mailbox will contain message without any recipient addresses specified. It means that the recipient was on BCC list.
Static addressing is not affected
There is no issue with static addressing offered by Narawen Inox POP3 Connector. It just grabs all the contents of mailbox and sends to target address regardless if the messages have any addressing information or not.
How to fix dynamic addressing for BCC addresses
For dynamic addressing Narawen Inox POP3 Connector must have valid recipient address available in order to route the mail properly.
Starting from version 5.2 SR2 this is supported by handling “x-rcpt-to” header added by some mail servers with hint what was the recipient e-mail address.
We recommend the upgrade to latest release to avoid problems with dynamic addressing caused by BCC field.
Applies to:
Narawen Inox POP3 Connector 5.2 SR1 (2008-02-05)
Narawen Inox POP3 Connector 5.2 (2007-11-14)
Narawen Inox POP3 Connector 5.1 SR1 (2006-09-25)
Narawen Inox POP3 Connector 5.1 (2006-06-14)
Narawen Inox POP3 Connector 5.0 (2005-11-10)
Leave a Comment » |
Narawen Inox POP3 Connector | Tagged: 5.0, 5.1, 5.1 SR1, 5.2, 5.2 SR1, addressing, bcc, inox |
Permalink
Posted by Narawen Software
February 3, 2009
To back up the configuration of Narawen Inox POP3 Connector use Registry Editor. All settings are stored at following registry key:
HKEY_LOCAL_MACHINE\SOFTWARE\Virtual Moon\Inox
Just export it to REG file and import in case of need.
Leave a Comment » |
Narawen Inox POP3 Connector | Tagged: backup, inox, Software |
Permalink
Posted by Narawen Software
February 3, 2009
Symptoms:
Messages bigger than 10 MB are not transferred by Narawen Inox POP3 Connector. They are downloaded from POP3 mailbox and retried to be sent without effect.
Additionally in Application event log InoxSvc records following message:
Report for message 1 of 1 from xxx@xxx
Delivery report:
Status: Not completed
xxx@xxx:
Not delivered. Connection to smtp://exchange-server:25 reported protocol error. 552 5.3.4 Message size exceeds fixed maximum message size.
Message details:
The hint is “fixed maximum message size”. Usually the limit is set in recipient policy. In that case increasing limit at recipient policy will not help. To adjust “fixed maximum message size” proceed with following steps:
- Exchange Server Management Console
- Organization Configuration
- Hub Transport
- Locate the appropriate Receive Connector
- Adjust the value of the Maximum Message Size (KB)
Leave a Comment » |
Exchange Server, Narawen Inox POP3 Connector | Tagged: configuration, exchange, inox, limit, size |
Permalink
Posted by Narawen Software
May 28, 2008
By default Narawen Inox POP3 Connector logs all information into Application event log related with messages being transferred. At busy systems it might flood event log with unnecessary information events. You can switch verbose logging off by proceeding with following steps:

- Open Administration Application.
- Right click at mail transfer host and select Properties menu option.
- Select Log tab.
- Select “Do not log detailed information events” option.
- Click OK button to save the changes.
- The InoxSvc service will be restarted to reflect the configuration changes.
From now on all information messages are disabled. Only warnings and errors will be put into event log.
Applies to:
Narawen Inox POP3 Connector 5.2 (2007-11-14)
Narawen Inox POP3 Connector 5.1 SR1 (2006-09-25)
Narawen Inox POP3 Connector 5.1 (2006-06-14)
Narawen Inox POP3 Connector 5.0 (2005-11-10)
Leave a Comment » |
Narawen Inox POP3 Connector, Software | Tagged: 5.0, 5.1, 5.1 SR1, 5.2, configuration, event, inox, log |
Permalink
Posted by Narawen Software
May 26, 2008

Affected product:
Narawen Inox POP3 Connector 5.1 SR1 (2006-09-25)
Symptoms:
When you try to uninstall or upgrade to newer version of Narawen Inox POP3 Connector you receive following error message:
This product requires Microsoft .NET Framework 2.0 component installed prior to installation. Download it from: http://www.microsoft.com/downloads/details.aspx?FamilyID=0856eacb-4362-4b0d-8edd-aab15c5e04f5
The message is shown even if computer have Microsoft .NET Framework 2.0 or higher installed. The uninstall/upgrade process is blocked.
Reason:
Due to bug in product installer routine responsible for Microsoft .NET Framework detection it can not detect framework versions higher than 2.0.
It causes the uninstaller to fail during launch and blocks uninstall or upgrade operation.
Solution:
Apply the fix provided by Narawen Software:
- Download and unzip a fix package inox_fix200801.zip.
- Run it at the computer where Narawen Inox POP3 Connector is installed.
Please note that the fix package requires administrator privileges to run.
- Click Start button to search for installed package and fix them if necessary.
After applying the fix you will be able to uninstall or upgrade the product.
Leave a Comment » |
Narawen Inox POP3 Connector, Software | Tagged: 5.1 SR1, inox, install, pop3 connector, uninstall, upgrade |
Permalink
Posted by Narawen Software